Flow and Pressure Dual Sensor

FD-EP series

Catalogues View Catalogue

Amplifier Units M12 connector type FD-EPA1C

FD-EPA1C - Amplifier Units M12 connector type

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

Software

  • CE Marking
  • CSA

Specifications

Model

FD-EPA1C

Type

M12 connector type*1

No. of control outputs

3

No. of analog outputs

1

No. of external inputs

2

Power supply cable

100-mm pigtail, M12 terminal, 8-pin

Response time (90% response)

Flow

50 ms/100 ms/250 ms/1 s/5 s (selectable, default 250 ms) *2

Pressure

2.5 ms/10 ms/50 ms/100 ms/250 ms/1 s/5 s (selectable, default 2.5 ms) *2

Input/output

Control output 1, 2, 3

Instantaneous flow/integrated flow/pressure/alert output/predictive maintenance output/seating (output 1 only)/pulse output NPN/PNP
setting switching, 3 output total: 100 mA max., residual voltage 2.5 V max.

Analog output

Instantaneous flow/pressure 4–20 mA/0–20 mA (switchable), load resistance 260 Ω or less

External inputs 1, 2

Zero flow/flow origin adjustment/atmospheric pressure correction/pressure zero shift/accumulation reset/application learning/application reset
Short-circuit current: 1.5 mA or less

Network compatibility

IO-Link*3

No. of expansion units

Protection circuit

Protection against reverse power connection, output overcurrent, output surges,
reverse output connection, head cable miswiring

Power supply

Power voltage

24 VDC +20%/−10% (including ripple), Class2/LPS

Power consumption

1870 mW (excluding load current)*4*5

Environmental resistance

Ambient temperature

-10 to +55°C (no freezing) *5

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2, 16 ms pulses, 1000 times each for X, Y, and Z directions

Material

Main unit: Polycarbonate, FG terminals: copper/iron

Weight

Approx. 42 g

*1 Ensure the cable length is 30 m or less (20 m or less when IO-Link is used) for the M12 connector type.
*2 Analogue output response time is 5 ms additional and 63% response.
*3 IO-Link: SpecificationV1.1/COM3 (230.4 kbps) is supported.
*4 Less than 190 mA including load.
*5 The operating ambient temperatures for the adjacent number of cable type/M12 connector type units and the number of zero line type expansion units should be 55°C for 1 to 2 units, 50°C for 3 to 5 units, and 45°C for 6 to 8 units. The prescribed values for the ambient temperature assume that the amplifier unit has been mounted on a DIN rail installed on a metal surface. Exercise special care when installing the product in an airtight space.