Air Efficiency Module
MP-F series
Single model NPT1 (25 A) MP-FN80
*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.
Specifications
Model | MP-FN80 | |||
Type | Single model | |||
Connection diameter | NPT1 (25 A) | |||
Supported fluids | Air, non-corrosive gases | |||
Supported fluid temperatures | –5 to +50°C | |||
Operating pressure range | 0.2 to 1 MPa *1 | |||
Pressure resistance | 1.5 MPa | |||
Flow | Detection principle | Thermal method (mass flow) | ||
Rated flow range (normal) | 12 to 8000 L/min | |||
Zero cut flow rate | 12 L/min, 0.7 m3/h | |||
Measurement accuracy | ±(1.5% of RD + 0.5% of F.S.) *2 *3 | |||
Repeatability | ±1.0% of F.S. (at averaging time of 1.0 s) | |||
Display resolution | 1 L/min, 0.1 m3/h | |||
Response time | 150 ms (63% response) *4 | |||
Averaging time | Select from OFF, 100 ms, 200 ms, 500 ms, 1.0 s, 3.0 s, 5.0 s, 10 s, 30 s | |||
Pressure (digital value, gauge pressure) | Rated pressure range | 0.000 to 1.000 MPa | ||
Measurement accuracy | ±2.0% of F.S. | |||
Repeatability | ±0.2% of F.S. (at 50 ms response time) | |||
Display resolution | 0.001 MPa | |||
Response time | Select from 10 ms/50 ms/100 ms/500 ms/1.0 s/5.0 s *4 | |||
Humidity (dew point) | Rated relative humidity range/dew point range | 15 to 100% RH (no condensation)/subject to relative humidity range *5 *6 | ||
Measurement accuracy | ±4°C *5 *6 | |||
Display resolution | 5%RH/1°C *5 *6 | |||
Temperature | Measurement accuracy | ±2.0°C *7 | ||
Display resolution | 0.1°C *7 | |||
Shutoff valve | Response time | Less than 1 s (closed > open) | ||
Leakage | 50 mL/min (N) or less | |||
Filter regulator (standard model only) | Pressure adjustment range | ─ | ||
Filtration rating | ||||
Drain cup capacity | ||||
Check valve | Available | |||
Display | Colour LCD, status indicators | |||
Data accumulation | Accumulation period | Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks | ||
Data reading | USB 2.0/Ethernet | |||
Input/output | Control output (Ch.1/2/3/4/5) | NPN/PNP setting switchable, Open collector output: 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA or less/Ch., Residual voltage: 2.5 V or less | ||
Analog output (Ch. 1/2) | 4-20 mA, Load resistance: 260 Ω or less *4 | |||
External input (Ch. 2/3/6) | Short circuit current: 1.5 mA or less; Input time: 20 ms or less | |||
Protection circuit | Protection against reverse power connection, power supply surges, reverse connection of inputs/outputs, input/output short circuits, output overcurrent | |||
Power supply | Power voltage | 24 VDC +25%/-20% (including ripple) Class 2 or LPS | ||
Current consumption | 1.2 A (300 ms) when the valve is open/closed, 100 mA *8 when the valve is not open/closed (when used alone, excluding load current) | |||
Communication interface | USB 2.0 | |||
Network compatibility | When using only this unit: IO-Link (Specification v1.1/COM3) *9 | |||
Environmental resistance | Enclosure rating | IP67 (IEC 60529) *10 | ||
Ambient temperature | −5 to +50°C (no freezing) *11 | |||
Relative humidity | 35 to 85% RH (no condensation) | |||
Vibration resistance | 10 to 500 Hz; Power spectral density: 0.204 G2/Hz; X, Y, and Z directions | |||
Shock resistance | 300 m/s2; 10 times each for X, Y, and Z directions | |||
Material | Sensor: PET/PPS/PBT/POM/Aluminium/SPHC | |||
Weight | Approx. 1920 g | |||
*1 The shutoff valve is subject to flow characteristic deterioration when the primary side pressure is less than 0.2 MPa (for standard models, the adjustment pressure of the filter regulator is 0.2 MPa or less). |