Short range amplifier unit with separate display Cable Type Main Unit FR-SA1

FR-SA1 - Short range amplifier unit with separate display Cable Type Main Unit

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

FR-SA1

Type

Short Separated Amplifier Unit Cable Main Unit

Response time

0.4 s, 1.5 s, 4 s (default value), 10 s

Output

No. of control outputs

Maximum 5

Control output/auxiliary output

NPN/PNP open collector (switchable) up to 30 VDC or less, max 50 mA for each
Total 750 mA or less for the entire amplifier when adding five or more expansion units
Residual voltage 1.4 V or less (50 mA or less)
N.O./N.C. switchable
IO5 used in combination with external input

Analogue output

0–20 mA/4-20 mA
Maximum load resistance 260 Ω
(Response time: 0.2 s (90% response) after control output is confirmed)

External input

Short circuit current: 1.5 mA or less Input time: 500 ms or more

External communication

Analogue output Precision

Resolution

1 mm *1

Zero accuracy

±0.1 mA
(zero point = 4 mA) *1

Full-scale accuracy

±0.2 mA
(full-scale = 20 mA) *1

Expansion

When added to FR-SA1 (FR-S01 connection): Up to 8 units
(9 units including the parent machine) *2
When added to FR-SA1 (FR-SH01 connection): Up to 12 units
(13 units including the parent machine) *2
When FR-SA2 is added to the NU Series: Up to 16 units *3

Power supply

Power voltage

24 VDC +25%/−20%*4*5 including ripple, Class2 or LPS

Power consumption

When FR-S01 is connected: up to 1940 mW or less (72 mA or less at 24 V)
When FR-SH01 is connected: up to 1560 mW or less (56 mA or less at 24 V)
(Excluding Load Current)

Environmental resistance

Ambient temperature

–20°C to +55°C (no freezing) *6

Relative humidity

Up to 85% RH (no condensation)

Protection circuit

Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges

Material

PC

Weight

Approx. 100 g

*1 This is the guaranteed value from verification performed at KEYENCE inspection facilities with a load resistance of 250 Ω. Measurement errors may occur depending on the customer’s environment.
*2 The number of expansion units can be increased by making the output current less than 750 mA in total. Contact your local KEYENCE representative for more details.
*3 Contact your local KEYENCE representative when adding more than the aforementioned number of units. When FR-S01 is connected: 6 units. When FR-SH01 is connected: 8 units.
*4 When expanding the FR-SA2 with the number of units indicated on the right or more, use a power voltage of 21.6 V or higher. When FR-S01 is connected: 1 unit; when FR-SH01 is connected: 8 units.
*5 When expanding the system by four or more FR-SA0 units with the FR-S01 connected or by ten or more FR-SA0 units with the FR-SH01 connected, use a power voltage of 21.6 V or higher.
*6 If the number of expansion units is one, the ambient temperature must be 50°C or less, and if the number of expansion units is two or more, the ambient temperature must be 45°C or less.

Data Sheet (PDF) Other Models