Amplifier Unit, DIN Rail Type IB-1050

IB-1050 - Amplifier Unit, DIN Rail Type

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • UL Listing(c/us)

Specifications

Model

IB-1050

Type

DIN rail mount

Main unit/Expansion unit

Expansion unit

Head compatibility

Yes

Display

Display resolution

0.01 %, 0.1 %, 1 % (switchable)

Display range

–99.999 to 99.999, –99.99 to 99.99
–99.9 to 99.9, –99 to 99 (switchable)

Digital display method

Dual7-segmentdisplay
Upper level: 5 red digits
Lower level: 5 green digits

Operation indicator

Judgment indicator: 2-color (green/red) LED (HI, GO, LO)
Bank indicator: Green LED x 4
Laser emission warning indicator: Green LED
Others: Green LED x 8, red LED x 3

Analogue output voltage

No

Analogue current output

Control Input

Bank switch input, zero shift input

Non-voltage input *1

Control input

Zero-shift input

Laser emission stop input

Timing input

Reset input

Adjust input

Control output

Judgment output (check output)

Open collector (NPN/PNP switchable, N.O./N.C. switchable) *2

Power supply

Power consumption

2400 mW or less (at 30 V, 80 mA max.) *3 *4 (including analog current output)

Power voltage

Supplied from main unit *3

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, compound amplitude 1.5 mm, 2 hours each for X, Y, Z axes

Material

Main unit case/Front panel: polycarbonate, keytop: polyacetal, cable: PVC

Weight

Approx. 140 g (including accessories)

*1 The four external input wires are assigned with desired inputs.
Rated no-voltage input: ON voltage 2 V or less, OFF current 0.05 mA or less
Rated voltage input: Max. input rating 30 V or less, ON voltage 7.5 V or more, OFF current 0.05 mA or less
*2 Rated NPN open collector output: Max. 100 mA/ch (20 mA/ch when expansion units are connected), 30 V or less, residual voltage 1 V or less
Rated PNP open collector output: Max. 50 mA/ch (20 mA/ch when expansion units are connected), power voltage or less, residual voltage 2 V or less
*3 Use with the over current protection device which is rated 30 V or more and not more than 1 A.
*4 Does not include the power consumption of the load.
The power consumption with expansion units installed is the total of each amplifier unit’s power consumption.
Example: When using one main unit (IB-1000) with two expansion units (IB-1050) (2400 mW X 1) + (2400 mW X 2) = 7200 mW

Data Sheet (PDF) Other Models