Compact model sensor head Standard model Colour IV4-G500CA

IV4-G500CA - Compact model sensor head Standard model Colour

*Please note that accessories depicted in the image are for illustrative purposes only and may not be included with the product.

Data Sheet (PDF)

Manuals

CAD Data

360°view (3D PDF)

Software

  • CE Marking
  • CSA

Specifications

Model

IV4-G500CA

Type

Standard model
[IV4-G500CA+OP-88909] Ultra-narrow field of view model

Installed distance

From 50 mm
[IV4-G500CA+OP-88909] 23 mm to 40 mm

Field of view

Installation distance of 50 mm: 22 (H) × 16 (V) mm to
Installation distance of 3000 mm: 1184 (H) × 888 (V) mm
(reference value)
[IV4-G500CA+OP-88909]
Installation distance of 23 mm: 9.8 (H) × 7.3 (V) mm to
Installation distance of 40 mm: 15 (H) × 11.2 (V) mm
(reference value)

Image receiving element

Type

1/2.9 inch colour CMOS

Number of pixels

1280 (H) × 960 (V)

Focus adjustment

Auto*1

Exposure time

12 µs to 9 ms*2

Lights

Illumination

White LED

Lighting method

Switchable between pulse and
continuous lighting

Indicators

2 indicators (both displaying same content)

Power supply

Average power consumption

2.5 W (without AI imaging illumination unit installed) 6.6 W (with AI imaging illumination unit installed)
[IV4-G500CA+OP-88909] 2.5 W

Environmental resistance

Enclosure rating

IP67 *3
[IV4-G500CA+OP-88909] —

Ambient temperature

0 to +50°C (no freezing)*4

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Frequency: 10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

500 m/s2 3 times in each of 6 directions

Material

Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *5

Weight

Approx. 75 g (no AI imaging illumination unit) Approx. 225 g (with AI imaging illumination unit)
[IV4-G500CA+OP-88909] Approx. 85 g

*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program.
*2 Maximum exposure time is 500 ms only when lighting is set to OFF.
*3 Except when polarising filters (OP-88642/OP-88643/OP-88646/OP-88647) are installed.
*4 When the operating ambient temperature exceeds 40°C, install in accordance with KEYENCE instructions, taking appropriate measures for heat dissipation to ensure that the case temperature does not exceed the rated 65°C. For the case temperature, measure the side with the “IV4 Series” label.
*5 ESD safe and IEC61340-5-1 compliant.