Ultra High Speed Sensing Ionizer Hybrid Type
SJ-E series
Specs Ultra High Speed Sensing Ionizer Hybrid Type SJ-E series
Model |
SJ-E036L |
SJ-E060L |
SJ-E084L |
SJ-E108L |
SJ-E132L |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method/ |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V *1 |
|||||||
Operating distance |
50 to 2000 mm |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm |
||||||||
Alarm output |
||||||||
Communication feature |
Remote control communication |
|||||||
Major features |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||||||
Effective length |
440 mm *3 |
680 mm *3 |
920 mm *3 |
1160 mm *3 |
1400 mm *3 |
|||
Total length |
350 mm |
560 mm |
800 mm |
1040 mm |
1280 mm |
|||
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
||||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
670 g |
850 g |
1070 g |
1270 g |
1500 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E156L |
SJ-E180L |
SJ-E204L |
SJ-E228L |
SJ-E252L |
SJ-E300L |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method/ |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V *1 |
||||||||
Operating distance |
50 to 2000 mm |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm |
|||||||||
Alarm output |
|||||||||
Communication feature |
Remote control communication |
||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
||||||||
Effective length |
1640 mm *3 |
1880 mm *3 |
2120 mm *3 |
2360 mm *3 |
2600 mm *3 |
3080 mm *3 |
|||
Total length |
1520 mm |
1760 mm |
2000 mm |
2240 mm |
2480 mm |
2960 mm |
|||
No. of electrodes |
25 |
29 |
33 |
37 |
41 |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1700 g |
1900 g |
2100 g |
2300 g |
2500 g |
2900 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E036H |
SJ-E060H |
SJ-E084H |
SJ-E108H |
SJ-E132H |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method/ |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V *1 |
|||||||
Operating distance |
50 to 2000 mm |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm |
||||||||
Alarm output |
||||||||
Communication feature |
Remote control communication |
|||||||
Major features |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||||||
Effective length |
420 mm *3 |
660 mm *3 |
900 mm *3 |
1140 mm *3 |
1380 mm *3 |
|||
Total length |
350 mm |
560 mm |
800 mm |
1040 mm |
1280 mm |
|||
No. of electrodes |
9 |
17 |
25 |
33 |
41 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
||||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
680 g |
870 g |
1100 g |
1300 g |
1550 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E156H |
SJ-E180H |
SJ-E204H |
SJ-E228H |
SJ-E252H |
SJ-E300H |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method/ |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V *1 |
||||||||
Operating distance |
50 to 2000 mm |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm |
|||||||||
Alarm output |
|||||||||
Communication feature |
Remote control communication |
||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
||||||||
Effective length |
1620 mm *3 |
1860 mm *3 |
2100 mm *3 |
2340 mm *3 |
2580 mm *3 |
3060 mm *3 |
|||
Total length |
1520 mm |
1760 mm |
2000 mm |
2240 mm |
2480 mm |
2960 mm |
|||
No. of electrodes |
49 |
57 |
65 |
73 |
81 |
97 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1750 g |
1950 g |
2150 g |
2350 g |
2600 g |
3000 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E036A |
SJ-E060A |
SJ-E084A |
SJ-E108A |
SJ-E132A |
|||
Image |
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
|||||||
Structure |
Shockless resistive coupling type |
|||||||
Voltage application method/ |
Pulse AC method/±8000 V |
|||||||
Ion balance control method |
Hi-Power I.C.C. method |
|||||||
Ion balance |
±30 V *1 |
|||||||
Operating distance |
50 to 2000 mm |
|||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||||||
Condition alarm |
||||||||
Alarm output |
||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
|||||||
Air connection port |
Rc 1/8 |
|||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||||||
Effective length |
420 mm *3 |
660 mm *3 |
900 mm *3 |
1140 mm *3 |
1380 mm *3 |
|||
Total length |
350 mm |
560 mm |
800 mm |
1040 mm |
1280 mm |
|||
No. of electrodes |
5 |
9 |
13 |
17 |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||||||
Overvoltage category |
I |
|||||||
Pollution degree |
2 |
|||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
||||||
Relative humidity |
35 to 85% RH (no condensation) |
|||||||
Material |
Electrode probe |
Tungsten |
||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||||||
Weight |
670 g |
850 g |
1070 g |
1270 g |
1500 g |
|||
*1 Measured under the following conditions. |
Model |
SJ-E156A |
SJ-E180A |
SJ-E204A |
SJ-E228A |
SJ-E252A |
SJ-E300A |
|||
Image |
|
|
|
|
|
|
|||
Ion generation method |
Corona discharge method |
||||||||
Structure |
Shockless resistive coupling type |
||||||||
Voltage application method/ |
Pulse AC method/±8000 V |
||||||||
Ion balance control method |
Hi-Power I.C.C. method |
||||||||
Ion balance |
±30 V *1 |
||||||||
Operating distance |
50 to 2000 mm |
||||||||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
|||||||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
|||||||
Condition alarm |
|||||||||
Alarm output |
|||||||||
Major features |
Condition alarm, ion level alarm, alarm output |
||||||||
Air connection port |
Rc 1/8 |
||||||||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
||||||||
Effective length |
1620 mm *3 |
1860 mm *3 |
2100 mm *3 |
2340 mm *3 |
2580 mm *3 |
3060 mm *3 |
|||
Total length |
1520 mm |
1760 mm |
2000 mm |
2240 mm |
2480 mm |
2960 mm |
|||
No. of electrodes |
25 |
29 |
33 |
37 |
41 |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
|||||||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
||||||||
Overvoltage category |
I |
||||||||
Pollution degree |
2 |
||||||||
Environmental resistance |
Ambient temperature |
0 to +40°C |
|||||||
Relative humidity |
35 to 85% RH (no condensation) |
||||||||
Material |
Electrode probe |
Tungsten |
|||||||
Body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
||||||||
Weight |
1700 g |
1900 g |
2100 g |
2300 g |
2500 g |
2900 g |
|||
*1 Measured under the following conditions. |