Compact Nozzle Static Eliminator

SJ-LM series

Catalogues View Catalogue

Specs Compact Nozzle Static Eliminator SJ-LM series

Model

SJ-L005M

SJ-L005MT

Image

Data Sheet (PDF)

Download

Download

Type

Nozzle type

Tube type

Voltage application method

High frequency AC method

High frequency AC method (68 kHz)

Applied voltage

2.2 kVAC

2.5 kVAC

Ion balance

±10 V*1

±10 V*6

Static elimination time

0.4 sec.*1

See Data Sheet.

Air supply pressure

0.05 to 0.5 MPa

Air supply temperature

0 to +50°C

Connection tube

Outer diameter: ø6, inner diameter: ø4

Ozone concentration

0.05 ppm or less*2

0.05 ppm or less*7

Control input

Static elimination stop input

Switchable between non-voltage input and voltage input
Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3

Reset input

LPC mode input

Control output

Alarm (N.C.)/Ion level alarm (N.O.)

Open-collector output 30 VDC or less,
50 mA max., residual voltage 1.5 V or less,
NPN/PNP settings switchable*3*4

Ratings

Power voltage

24 VDC ±10% (including ripple) or
12 VDC (dedicated AC adapter OP-88020/87722*5)

Current consumption

0.2 A or less (24 VDC)
0.3 A or less (12 VDC)

Environmental resistance

Ambient temperature

0 to +50°C (0 to +40°C when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT
Cable: PVC, TPE, copper alloy
Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating
Fitting: Brass + electroless Ni plating, POM, NBR

Weight

Approx. 60 g

Approx. 65 g

*1 Measurement results taken with an installation distance of 150 mm, air supply pressure of 0.2 MPa, and a nozzle angle of 90° (typical values)
*2 Measurement results taken with an installation distance of 100 mm, air supply pressure of 0.1 MPa, and a nozzle angle of 90° (typical values)
*3 Cannot be used when the power supply is the AC adapter.
*4 To use the ion level alarm with the tube type, use it with air supply pressure of 0.3 MPa or less.
*5 Rated input of 100 to 240 VAC, 50/60 Hz
*6 Measurement results taken with tube length of 500 mm, an installation distance of 50 mm, and air supply pressure of 0.2 MPa (typical values)
*7 Measurement results taken with tube length of 500 mm, an installation distance of 300 mm, and air supply pressure of 0.1 MPa (typical values)

Back to top